As a "P" model, it fully supports parallel operation of up to 6 units, allowing the system to scale from 8kW to 48kW of split-phase output as energy demands grow. With 160A of programmable PV charging current, 12000VA of peak surge power, 5HP motor starting capability and dual lithium battery activation, it is equally suited to whole-home backup, off-grid and self-consumption applications — all in a lightweight 580 × 359 × 127 mm, 15.9 kg enclosure.
Certified to UL 1741 with FCC Part 15 Class B compliance, the GES4880M160-500P provides professional-grade safety and performance for residential energy independence.
● True Split Phase Output — 120Vac (L1/N, L2/N) / 240Vac (L1/L2) pure sine wave output with five selectable voltage levels per phase (100/105/110/120/127Vac), matching standard North American panel wiring.
● 8kW Continuous / 12000VA Peak Power — 8kW split phase rated output (6kW per phase), 12000VA split phase surge (9000VA single phase) and 5HP motor starting capability for hard-starting loads such as air conditioners and well pumps.
● 160A PV Charging / 170A Discharge Current — Up to 160A of programmable PV charging current, 120A AC charging and 170A rated battery discharge current — enough to support large battery banks of 160Ah or more.
● Dual MPPT with 10000W PV Input — Two independent MPPT trackers with 99.9% tracking efficiency, 5000W + 5000W maximum PV input power, 18A + 18A input current, 500Vdc maximum open-circuit voltage and 120Vdc start-up voltage for flexible string design.
● Parallel Capability up to 48kW — Up to 6 units can operate in parallel (P model), scaling the system to 48kW of split phase output for larger residential or light-commercial applications, with dedicated parallel communication ports.
● Dual Activation of Lithium Battery — A dormant lithium battery can be triggered/activated by either mains or solar power, and works with 15 BMS communication protocols including Pylon, Gotion, Dyness, Fox-ess, Sunwoda and Voltronic.
● Battery-Free Operation — Can be used without a battery: solar and utility grid can power loads at the same time, dramatically lowering system entry cost.
● Four Charging Modes + Scheduled Charge/Discharge — Only Solar, Mains Priority, Solar Priority and Mains & Solar hybrid charging modes, with sectional (time-period) charge and discharge settings for time-of-use optimization.
● Anti Feed-In & Self-Consumption — CT sampling detection prevents excess export to the grid and enables whole-house self-consumption from solar, battery and grid hybrid supply.
● Touch Screen LCD + 10ms Transfer — Resistive touch LCD with dynamic power-flow diagram for intuitive system monitoring; 10ms typical conversion time between bypass and inverter output for uninterrupted power supply; power saving mode reduces no-load loss when per-phase load is ≤25W.
3/4 Front View
Front View
|
Parameter |
Value |
|
Rated Input Voltage |
120Vac (L1/N, L2/N) / 240Vac (L1/L2) |
|
Input Phase Voltage Range |
(85Vac ~ 140Vac) ±2% |
|
Input Frequency |
50Hz/60Hz auto detection (47~55Hz / 57~65Hz range) |
|
Output Waveform |
Pure sine wave |
|
Rated Output Power (Split Phase) |
8000VA / 8000W |
|
Rated Output Power (Single Phase) |
6000VA / 6000W |
|
Peak Power |
12000VA (split phase) / 9000VA (single phase) |
|
Loaded Motor Capability |
5HP |
|
Output Voltage |
120Vac (L1/N, L2/N) / 240Vac (L1/L2), ±5% |
|
Output Frequency |
50Hz±0.3Hz / 60Hz±0.3Hz |
|
Power Factor |
1 |
|
Overload Protection |
105%<load<110%: shut off after 5 min; 110%<load<125%: shut off after 10 s; load>125%: shut off after 5 s |
|
Output Short Circuit Protection |
Continuous short circuit 200ms protect |
|
Maximum Bypass Phase Overload Current |
2-pole, 50A/50A (L1/L2) |
|
Bypass Circuit Breaker Specification |
2-pole, 50A/50A (L1/L2) |
|
AC Charge Input Circuit Breaker |
2-pole, 50A/50A (L1/L2) |
|
Conversion Time (Bypass and Inverter) |
10ms (typical) |
|
AC Reverse Protection |
Yes |
|
AC Input Wiring (Split Phase) |
8.37mm²/8AWG, breaker 3P—63A, torque 1.2-1.6Nm |
|
AC Output Wiring (Split Phase) |
5.26mm²/10AWG, breaker 3P—40A, torque 1.2-1.6Nm |
|
Efficiency |
AC charging >95%; inverter output >93% |
|
Parameter |
Value |
|
Rated Battery Input Voltage |
51.2V (minimum starting voltage 44V) |
|
Battery Voltage Range |
40.0Vdc ~ 58.6Vdc (alarm/shutdown/recovery settable on LCD) |
|
Battery Types |
Lead-acid and lithium battery |
|
Max AC Charge Current (settable) |
120A (±5Adc) |
|
Charge Voltage Range |
40 – 58.6Vdc |
|
Rated Battery Discharge Current |
170A |
|
Max PV Charge Current (settable) |
0 – 160A |
|
Max Hybrid Charge Current (AC+PV, settable) |
0 – 160A |
|
Lithium BMS Protocols |
Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, PylonV3.5, Pylon Can, EVI, Voltronic (15 protocols) |
|
Lithium Activation |
Dual activation — dormant battery can be triggered by mains or solar |
|
Recommended Battery Capacity |
≥160Ah |
|
Battery Cable / Breaker |
33.6mm²/2AWG, 2P—250A breaker, torque 4-5Nm |
|
Charging Short Circuit Protection |
Circuit breaker or blown fuse |
|
Parameter |
Value |
|
Number of MPPT Groups |
2 (independent, 99.9% tracking efficiency) |
|
Maximum PV Input Power |
5000W + 5000W |
|
Maximum PV Input Current |
18A + 18A |
|
Maximum PV Open Circuit Voltage |
500Vdc |
|
PV Start-up Voltage |
120Vdc |
|
PV Operating Voltage Range |
90Vdc ~ 485Vdc |
|
MPPT Voltage Range |
90Vdc ~ 450Vdc |
|
PV Wiring / Breaker |
3.31mm²/12AWG, 2P—25A breaker, torque 1.2-1.6Nm |
|
Wiring Protection |
Reverse polarity protection; charging short circuit protected by blown fuse |
|
Parameter |
Value |
|
Permitted Parallel Number |
1 ~ 6 units (dedicated parallel communication port) |
|
Certification |
UL 1741 |
|
EMC Certification |
FCC Part 15, Class B |
|
Communication Interface |
USB / RS485 (WiFi/GPRS optional) / Dry contact control |
|
Operating Temperature Range |
-10°C to 55°C (>45°C derating) |
|
Storage Temperature Range |
-25°C ~ 60°C |
|
Humidity Range |
5% to 95% (conformal coating protection) |
|
Noise |
≤60dB |
|
Heat Dissipation |
Forced air cooling, variable speed fan |
|
Power Saving Mode |
Enters when load per phase is null or ≤25W |
|
Size (L×W×D) |
580mm × 359mm × 127mm |
|
Weight |
15.9kg |
● Whole-Home Backup Power — 8kW split phase output with 12000VA surge and 5HP motor starting keeps central air conditioners, well pumps and other hard-starting 240V appliances running through outages, with 10ms automatic transfer.
● Scalable Residential Solar Storage — Start with one unit and expand to 6 in parallel (up to 48kW) as household consumption or battery capacity grows.
● Self-Consumption & Time-of-Use Savings — CT-based anti feed-in detection plus scheduled charge/discharge periods let owners store cheap solar or off-peak grid energy and discharge during peak-rate hours.
● Off-Grid Homes & Light Commercial — Dual MPPT inputs up to 10000W of PV, lithium dual activation and battery-free operation provide flexible, low-entry-cost energy autonomy.
Yes. It supports battery-free operation — solar and utility grid can power loads at the same time. You can add batteries later; the system also enters a power saving mode (per-phase load ≤25W) to cut no-load losses.
The 8KW 48V split phase 120V 240V hybrid PV inverter works with 15 BMS communication protocols: Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, PylonV3.5, Pylon Can, EVI and Voltronic. Lead-acid batteries are also supported.
The 8KW 48V split phase 120V 240V hybrid PV inverter has a dual activation function: a dormant lithium battery can be triggered (woken up) by either mains/grid power or solar power, without needing external equipment.
It delivers 12000VA of split-phase surge power with 5HP loaded motor capability, which covers most residential air conditioners, well pumps and other hard-starting motor loads. For sustained motor running, make sure continuous load stays within the 8kW rating.
Each MPPT accepts up to 5000W / 18A with a 500Vdc maximum open-circuit voltage, 120Vdc start-up voltage and 90–450Vdc MPPT range. Keep string Voc below 500Vdc (including at cold temperatures) and above 120Vdc for start-up. Use 12AWG PV wiring with a 2P—25A breaker per tracker.
Yes — this is the "P" (parallel) model. Up to 6 units can operate in parallel with dedicated parallel communication cabling, scaling output up to 48kW of split phase power.
No. This 8KW 48V split phase 120V 240V hybrid PV inverter is not certified for grid-tie (feed-in) operation. The CT-based anti feed-in function is designed to prevent export and enable self-consumption only. Applications should be off-grid, backup or zero-export; please comply with local electrical codes.
The inverter switches between bypass and inverter output in typically 10ms, so connected loads keep running essentially uninterrupted.
A battery bank of at least 160Ah at 48V (51.2V nominal) is recommended. Use 2AWG (33.6mm²) battery cables with a 2-pole 250A DC breaker and torque terminals to 4-5Nm.
Yes. The sectional charge/discharge function lets you set specific time periods for battery charging or discharging — ideal for charging from the grid at off-peak rates and discharging during peak hours.
Yes. Communication options include USB, RS485, optional WiFi/GPRS dongles for remote monitoring, and a dry contact port for external control. The touch screen LCD shows a dynamic power-flow diagram of the whole system locally.
UL 1741, with FCC Part 15 Class B EMC compliance.
The unit measures 580 × 359 × 127mm and weighs just 15.9kg, wall-mounted with the included bracket. Please confirm the packing list (user manual, mounting accessories, CT sensors, communication parts) with your supplier at order time, and follow the manual's safety instructions during installation.