The GES4862M120-500 outputs a true split-phase 120/240Vac sine wave with 6200VA rated power, 9300VA of peak power and the ability to start a 3HP motor. Its single-string MPPT accepts up to 9000W of PV input (500Vdc max open-circuit voltage, 120Vdc start-up) and charges the 48V battery bank at up to 120A, while utility charging adds another 100A - keeping large battery banks ready around the clock. It runs lithium batteries (15 BMS protocols, dual activation) or lead-acid, and can even operate without a battery for zero-export self-consumption.
Certified to UL 1741 with FCC Part 15 Class B EMC compliance, the 6.2KW 48V split phase 120V 240V hybrid PV inverter features a color touch-screen LCD, 10ms typical transfer time, programmable time-of-use charging, and a compact 483 x 339 x 127 mm, 11.5 kg housing that mounts easily in a garage or utility room.
● True split-phase output: 120Vac (L1/N, L2/N) / 240Vac (L1/L2) pure sine wave, selectable output voltage of 100/105/110/120/127Vac for flexible loads.
● GES4862M120-500 delivers 6200VA rated split-phase power (4800VA single-phase) with 9300VA peak (7200VA single-phase) and 3HP motor-starting capability - runs air conditioners, pumps and shop tools.
● High-current charging: 120A adjustable PV charge current, 100A AC charge current, and 140A rated battery discharge current for heavy loads.
● 9000W single-string MPPT input: 500Vdc max PV open-circuit voltage, 120Vdc start-up, 90-485Vdc operating range, up to 27A input current.
● Lithium-ready with dual activation: supports 15 lithium BMS protocols (Pylon, Dyness, Fox-ess, Gotion, Sunwoda, Aoguan, Oulite, CF, Pace, BST, AEC, Pylon V3.5, Pylon CAN, EVI, Voltronic) via CAN or RS485; lead-acid (AGM/GEL/flooded) supported as well.
● Batteryless operation: works as a grid-tie-free solar supplier for zero-export self-consumption when no battery is connected (system-dependent).
● Four charging modes (Solar Only, Utility First, Solar First, Solar and Utility) plus programmable time-of-use charge/discharge windows to maximize solar use and exploit utility peak-valley price differences.
● Built-in anti-backflow current limiting via external CT - self-consumption without exporting excess energy to the grid.
● Color touch-screen LCD for real-time monitoring and parameter setting; USB / RS485 (/WiFi/GPRS optional) communication plus dry-contact control.
● Fast 10ms typical transfer between bypass and inverter mode keeps computers and home electronics running through outages.
3/4 Front View
Front View with Touch-Screen LCD
3/4 View (Left)
Side View (Right): Heat Dissipation Vents and Battery Switch
Side View (Left): AC Input/Output Glands and Ventilation
Bottom Panel: AC IN/OUT, USB, WiFi, RS485-2 BMS-CAN, Dry Contact, CT Inputs, Parallel Connection and Battery/PV Terminals
Technical parameters of the GES4862M120-500 split phase hybrid inverter, verified against the manufacturer datasheet (V3.0):
|
Parameter |
Value |
|
Rated input voltage |
120Vac (L1/N, L2/N) / 240Vac (L1/L2), split phase |
|
Input phase voltage range |
(85Vac ~ 140Vac) +/-2% |
|
Input frequency |
50Hz / 60Hz auto detection (47~55Hz / 57~65Hz) |
|
Maximum efficiency of utility charging |
>95% |
|
Conversion time (bypass and inverter) |
10ms typical |
|
Rated output power (VA/W) |
Split phase: 6200 / Single phase: 4800 |
|
Peak power |
Split phase: 9300VA / Single phase: 7200VA |
|
Loaded motor capability |
3HP |
|
Output voltage / waveform |
120Vac (L1/N, L2/N) / 240Vac (L1/L2), pure sine wave, +/-5% |
|
Output frequency |
50Hz / 60Hz +/-0.3Hz |
|
Maximum efficiency of inverter output |
>93% |
|
Overload protection |
105-110%: 5 min; 110-125%: 10 s; >125%: 5 s |
|
Output short circuit protection |
Continuous short circuit 200ms protect |
|
Maximum bypass overload current |
2-pole, 40A/40A (L1/L2) |
|
Recommended AC wiring / breaker (input) |
12AWG (3.31mm2), 3P-40A (split phase), torque 1.2-1.6Nm |
|
Recommended AC wiring / breaker (output) |
12AWG (3.31mm2), 3P-32A split phase (26A bypass), 2P-40A single phase |
|
Parameter |
Value |
|
Rated battery input voltage |
51.2V (minimum starting voltage 44V) |
|
Battery voltage range |
40.0-58.6Vdc (alarms and thresholds settable on LCD) |
|
Battery type |
Lead acid and lithium battery |
|
Maximum AC charge current (settable) |
100A +/-5A |
|
PV charge current (settable) |
0-120A |
|
Hybrid max charge current (AC+PV, settable) |
0-120A |
|
Rated battery discharge current |
140A |
|
Charge voltage range |
40-58.6Vdc |
|
Recommended battery cable / breaker |
2AWG (33.6mm2), 140A discharge / 120A charge, 2P-200A breaker, torque 2-3Nm |
|
Suggested battery capacity |
>=160Ah |
|
Lithium BMS protocols |
Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, Pylon V3.5, Pylon CAN, EVI, Voltronic (RS485 or CAN) |
|
Parameter |
Value |
|
Number of MPPT groups |
1 |
|
Maximum PV input power |
9000W |
|
Maximum PV open circuit voltage |
500Vdc |
|
PV start-up voltage |
120V |
|
PV operating voltage range |
90-485Vdc |
|
MPPT voltage range |
90-450Vdc |
|
Maximum PV input current |
27A |
|
Recommended PV wiring / breaker |
12AWG (3.31mm2), 2P-32A, torque 1.2-1.6Nm |
|
PV wiring protection |
Reverse polarity protection; charging short circuit protection (fuse) |
|
Parameter |
Value |
|
Parallel capability |
Standard model: NO; GES4862M120-500P variant: 1-6 units |
|
Certification |
UL 1741 |
|
EMC certification |
FCC Part 15 Class B |
|
Operating temperature range |
-10C to 55C (>45C derating) |
|
Storage temperature range |
-25C to 60C |
|
Humidity range |
5% to 95% (conformal coating protection) |
|
Noise |
<=60dB |
|
Heat dissipation |
Forced air cooling, variable-speed fan |
|
Communication interface |
USB / RS485 (/WiFi/GPRS) / dry node control |
|
Power saving mode |
Self-consumption when load per phase <=25W |
|
Size (L*W*D) |
483 x 339 x 127 mm |
|
Weight |
11.5 kg |
Whole-home backup: the GES4862M120-500 keeps 240V well pumps, HVAC and 120V household circuits alive through grid outages with a 48V battery bank.
Off-grid homes and cabins: 9000W of PV input on a single MPPT string simplifies array design for remote installations.
Self-consumption with zero export: pair the hybrid inverter with the external CT to limit back-feed and cut utility bills without grid-tie certification concerns.
Garage and workshop installs: compact 483 x 339 x 127 mm, 11.5 kg wall-mount housing fits tight utility spaces.
The GES4862M120-500 produces true split-phase 120/240Vac power - two 120Vac legs (L1/N, L2/N) plus 240Vac across L1/L2 - so it can run standard household circuits and 240V appliances like well pumps, dryers and mini-splits at the same time.
It delivers 6200VA continuous split-phase power (4800VA on single phase) with a 9300VA split-phase peak and 3HP motor-starting capability. Overload tolerance is 105-110% for 5 minutes, 110-125% for 10 seconds, and above 125% for 5 seconds.
The MPPT accepts up to 9000W of PV input with a maximum open-circuit voltage of 500Vdc and 27A maximum input current. Design your string so that Voc stays under 500V even at the coldest site temperature; the MPPT starts harvesting at just 120Vdc.
The 6.2KW 48V split phase 120V 240V hybrid PV inverter works with lead-acid (AGM, GEL, flooded) and lithium batteries. For lithium, the built-in CAN/RS485 BMS communication supports 15 protocols including Pylon, Dyness, Fox-ess, Gotion and Sunwoda; dual activation lets the inverter wake or be woken by the battery.
Suggested capacity is at least 160Ah (48V). Use 2AWG (33.6mm2) battery cables rated for the 140A discharge current, protected by a 2P-200A breaker, with terminals torqued to 2-3Nm. For lead-acid, set charge current near 0.2C of battery capacity.
The standard GES4862M120-500 does not support parallel operation. If you need expansion from 1 to 6 units, choose the GES4862M120-500P variant; for larger systems consider the GES48 8kW/10kW/12kW/16kW split-phase models.
Yes, the inverter can supply PV or utility power directly to loads without a battery for zero-export self-consumption applications (specifications may differ from battery mode; note this model is not grid-tie certified).
Yes. Programmable time-period charge and discharge windows let you charge from cheap utility power at night and discharge during expensive peak hours, or prioritize solar self-consumption during the day.
Connect the supplied external current transformer (CT) at the grid entry point; the inverter limits its export so no excess energy flows back to the grid - useful where feed-in is not permitted.
Transfer time between bypass and inverter mode is typically 10ms, fast enough that most electronics continue operating without interruption.
Yes. USB and RS485 ports are built in, with optional WiFi or GPRS modules for remote monitoring, plus a dry-contact port for external control signals.
The GES4862M120-500 is certified to UL 1741 with FCC Part 15 Class B EMC compliance. Note it is not certified for grid-tie export, so use it in off-grid, backup or zero-export self-consumption systems.
Each package contains the 6.2KW 48V split phase 120V 240V hybrid PV inverter, external CT and user manual. The unit measures 483 x 339 x 127 mm, weighs 11.5 kg, and mounts on the wall with four M4/M5 screws.
Address
No. 82, Xiaotang Gongye Avenue, Shishan Town, Nanhai District, Foshan City, Guangdong Province, China
Tel