Despite its size, it is generously equipped: a high-voltage MPPT accepting up to 6,000W of PV input at 500Vdc maximum open-circuit voltage, up to 120A of programmable charging current (80A from AC, 120A from PV or hybrid) and a 140A rated discharge current, plus a 7,200VA peak capacity with 2HP motor-starting for pumps, refrigerators and power tools. Built-in CAN/RS485 BMS communication supports 16 lithium battery brands plug-and-play, dormant lithium batteries can be activated by either mains or PV, and the unit can even run without a battery. With four charging strategies, timed charge/discharge windows, generator dry-contact auto-start, external-CT zero-export self-consumption and 10ms typ. UPS-grade transfer, the 3.6KW 24V single phase 120V hybrid PV inverter is an ideal entry point into whole-home solar backup and off-grid living.
1. 120Vac single-phase pure sine wave output — Full digital voltage/current double closed-loop control with advanced SPWM technology for clean, stable power.
2. 3.6kW continuous / 7.2kVA peak power — 3,600VA/W rated output with 7,200VA peak capacity and 2HP motor-starting capability for refrigerators, well pumps and power tools.
3. 120A high-current charging, 140A discharge — Up to 120A PV charging (programmable), 80A AC charging and 120A hybrid charging, with a rated battery discharge current of 140A.
4. High-voltage single MPPT with 6kW PV input — MPPT tracker accepting up to 6,000W and 27A, with 500Vdc max open-circuit voltage, 120Vdc start-up and 99.9% tracking efficiency.
5. 24V battery platform — Wide battery voltage window of 20.0–33.0Vdc with preset parameters for GEL/SLD/FLD lead-acid and LF07/LF08/LF09 lithium-iron-phosphate batteries.
6. Lithium-ready with dual activation — CAN/RS485 BMS communication with pre-configured protocols for Pylon, Dyness, Fox-ess, Gotion, Sunwoda, Tentek and more; dormant lithium batteries can be activated by either mains or PV.
7. Works without battery — PV and utility can power loads directly even with no battery installed; also supports generator input with a dry-contact auto-start port for 24/7 off-grid operation.
8. Four charging modes & timed charge/discharge — Solar-only, Mains-priority, Solar-priority and Hybrid charging, with programmable time windows for scheduled charging/discharging to exploit time-of-use tariffs.
9. Anti feed-in & self-consumption — With an optional external CT, the inverter performs whole-house anti-backflow control and prioritizes self-consumption of solar energy.
10. Intelligent LCD & full connectivity — LCD with system status icons, three LED status indicators and four function keys, USB / RS485 / WiFi (optional) monitoring, dry-contact control, power-saving mode (load ≤ 25W) and 10ms typ. transfer between bypass and inverter output.
Front View
Product Rendering
|
Parameter |
Value |
|
Rated input voltage |
120Vac ±5% |
|
Input voltage range |
(90–140Vac) ±2% |
|
Input frequency |
50Hz / 60Hz (auto detection) |
|
Input frequency range |
47–55Hz (50Hz); 57–65Hz (60Hz) |
|
Max bypass overload current |
40A |
|
Bypass efficiency |
>95% |
|
Conversion time (bypass ↔ inverter) |
10ms (typical) |
|
Rated output power |
3,600VA / 3,600W |
|
Peak power |
7,200VA |
|
Output waveform |
Pure sine wave |
|
Rated output voltage |
120Vac |
|
Output voltage error |
±5% |
|
Output frequency |
50Hz ±0.3Hz / 60Hz ±0.3Hz |
|
Power factor |
1 |
|
Max inverter efficiency |
>91% |
|
Loaded motor capability |
2HP |
|
Overload protection |
102%–110%: shut down after 5 min; 110%–125%: after 10 s; >125%: after 5 s (M series) |
|
Output short-circuit protection |
Circuit breaker |
|
Parameter |
Value |
|
Battery type |
Lead-acid (GEL / SLD / FLD) or Lithium-iron-phosphate (LF07 / LF08 / LF09) |
|
Rated battery input voltage |
28.8V (minimum starting voltage 22V); 24V nominal battery platform |
|
Battery voltage range |
20.0–33.0Vdc ±0.6Vdc (alarm / cutoff / recovery points settable on LCD) |
|
Max AC charging current |
80A (settable) |
|
Max PV charging current |
120A (settable, 0–120A) |
|
Max hybrid charging current (AC + PV) |
120A (settable, 0–120A) |
|
Rated battery discharge current |
140A |
|
Charge current error |
±5Adc |
|
Lithium BMS communication |
RS485 / CAN (RS485-2/BMS port) |
|
Supported BMS protocols |
Voltronic, Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, Pylon V3.5, MeZic, Tentek, PLN-CAN |
|
Lithium battery dual activation |
Activated by mains or PV when battery is dormant |
|
Power-saving mode threshold |
Load ≤ 25W |
|
Parameter |
Value |
|
Max PV array power |
6,000W |
|
Max PV open-circuit voltage |
500Vdc |
|
PV operating voltage range |
90–500Vdc |
|
MPPT voltage range |
90–450Vdc |
|
Start-up voltage |
120Vdc |
|
Max PV input current |
27A |
|
MPPT tracking efficiency |
99.9% |
|
PV wiring / breaker recommendation |
12AWG (3.31mm²) cable, 2-pole 32A DC breaker |
|
Parameter |
Value |
|
Parallel operation |
Not supported |
|
Battery wiring / breaker recommendation |
2AWG (33.6mm²) cable, 2-pole 160A breaker, torque 2–3Nm |
|
AC input/output wiring recommendation |
12AWG (3.31mm²) cable, 2-pole 40A breaker, torque 1.2–1.6Nm |
|
Certification |
UL 1741; CE (IEC 62109-1/-2) |
|
EMC level |
FCC Part 15 Class B; EN 61000 C2 |
|
Operating temperature |
−10°C to 55°C |
|
Storage temperature |
−25°C to 60°C |
|
Humidity |
5%–95% (conformal coating protection) |
|
Noise |
≤60dB |
|
Cooling |
Forced air cooling with variable-speed fan |
|
Communication interfaces |
USB / RS485 (WiFi/GPRS optional) / dry contact / external CT |
|
Dimensions (W × H × D) |
428 × 280 × 110mm |
|
Weight |
8.2kg |
11. Essential-load backup power — Keeps refrigerators, lighting, internet equipment, security systems and select 120V appliances running through outages, with a 10ms typ. transfer that feels like a UPS.
12. Off-grid homes, cabins and RV outbuildings — With 6kW of PV input capacity and generator auto-start via the dry contact port, the unit forms a complete off-grid power system on a cost-effective 24V battery platform.
13. Self-consumption and time-of-use optimization — With the optional external CT, solar energy is prioritized for household loads with whole-house anti-backflow control; scheduled charge/discharge windows let the battery charge at off-peak rates and discharge during peak-price hours.
14. Compact light-duty power — At just 8.2kg and 428 × 280 × 110mm, the unit is easy to wall-mount in garages, utility rooms, tiny homes, boats and telecom cabinets where space is limited.
Yes. The 3.6KW 24V single phase 120V hybrid PV inverter supports battery-less operation: PV power and utility power can supply your loads simultaneously even with no battery installed. This makes it usable as a pure grid-tied backup solution, with the option to add batteries later. Note that when no battery is present, the inverter cannot provide backup during a grid outage at night.
The 3.6KW 24V single phase 120V hybrid PV inverter supports 24V lead-acid batteries (select GEL, SLD or FLD type, with preset charge parameters) and 24V lithium-iron-phosphate batteries (select LF07, LF08 or LF09 according to cell count). BMS communication runs over RS485 or CAN via the RS485-2/BMS port, with pre-configured protocols for Voltronic, Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, Pylon V3.5, MeZic, Tentek and PLN-CAN — simply connect the battery's BMS cable and select the matching protocol in the menu.
We suggest a 24V battery bank of at least 200Ah. For lithium batteries, a 200Ah bank accepts the 120A charging current at 0.6C; for lead-acid batteries, the recommended charge current is 0.2C, so a bank of 600Ah is ideal to use the full charging capability — or limit the settable charge current to match a smaller bank. Charging parameters (charge voltage, cutoff and recovery points) are all adjustable on the LCD.
The unit delivers 3.6kW continuous power with a 7,200VA peak capacity and a rated motor-starting capability of 2HP — suitable for refrigerators, small well pumps, fans and power tools. Overload handling is progressive: 102%–110% load runs for 5 minutes, 110%–125% for 10 seconds, and above 125% for 5 seconds before shutdown. For large compressors, consider sizing up to the 6.2kW SPI4862M120-500 (3HP) model.
The MPPT accepts a maximum of 6,000W and 27A input. Keep the array's open-circuit voltage at or below 500Vdc (absolute maximum), stay within the 90–450Vdc MPPT window, and note that tracking starts at 120Vdc. Series and parallel string combinations are both supported as long as these limits are respected; install a 2-pole 32A DC breaker between the PV array and the inverter and use 12AWG PV wire. Never connect one PV string to more than one inverter.
No. The SPI2436M120-500 does not support parallel operation. If your project needs higher capacity, consider our larger single-phase or split-phase hybrid inverters — the 6.2kW SPI4862M120-500P and the 12kW/16kW GES48 series support up to 6 units in parallel. Contact our sales team to confirm the right model for your project.
The 3.6KW 24V single phase 120V hybrid PV inverter works with an optional external CT sensor for whole-house anti-backflow (zero export) and self-consumption control: it dynamically matches the load power so that no current is injected into the grid. Please note this inverter does not carry grid-interconnection certification, so this functionality is intended for off-grid or export-limited applications only — confirm local regulations before any grid-interactive installation.
In bypass mode, the unit switches from grid to inverter output in a typical 10ms, comparable to a line-interactive UPS, so most electronics continue running without interruption. Two output modes are available (mains bypass and inverter output), and PV charging continues unaffected during the switchover.
When the load on the output stays at or below 25W, the inverter can enter power-saving mode to cut no-load self-consumption. This is useful for overnight periods or seasonal properties with minimal standby loads; the mode can be enabled or disabled in the settings menu.
Programmable time windows let you set when the battery charges and when it discharges. For example, you can allow grid charging only during off-peak night hours and force battery discharge during expensive evening peak hours, maximizing savings under time-of-use tariffs. The inverter also supports four charging strategies: solar-only, mains-priority, solar-priority and hybrid charging.
Out of the box, the unit offers an LCD with system status icons, three LED indicators (AC OUT / CHARGE / FAULT) and four function keys, plus USB and RS485 ports for PC monitoring. An optional WiFi/GPRS dongle enables remote monitoring of system status, real-time power flow, historical data and fault alarms from a phone or PC. A dry-contact port can auto-start/stop a diesel generator based on battery voltage.
The 3.6KW 24V single phase 120V hybrid PV inverter provides 360° all-round protection: PV reverse-polarity and night reverse-current protection, PV over-voltage/over-current protection, battery over/under-voltage and over-current protection, output overload and circuit-breaker short-circuit protection, AC input over-voltage and AC reverse protection, over-temperature protection with variable-speed fan cooling, and battery input fuse protection.
Each package contains the inverter × 1, user manual × 1, ring terminal × 2 and dust cap × 2. Warranty terms follow the warranty card included with your unit — please contact our sales team for detailed warranty policies and extended service options for your region.
Address
No. 82, Xiaotang Gongye Avenue, Shishan Town, Nanhai District, Foshan City, Guangdong Province, China
Tel