Compared with standard models in the series, the XP version features the industry-leading 250A maximum battery charging current (270A discharge) and a massively oversized PV input of 12,000W + 12,000W across two independent MPPTs with 32A+32A input current — fully compatible with today's high-current 210mm/182mm PV modules. Built-in CAN/RS485 BMS communication supports 13+ lithium battery brands for plug-and-play integration, and up to 6 units can be paralleled for systems up to 72kW.
Whether used as a whole-home backup power center, a complete off-grid energy system, or a self-consumption solar solution with zero export, the GES48120M250-500XP provides uninterrupted, 360°-protected power around the clock.
1. Complete 120/240Vac split-phase output — Pure sine wave output of 120Vac per phase and 240Vac between phases, with selectable 100/105/110/120/127Vac voltage levels per phase; supports single-phase, split-phase and parallel configurations.
2. 12kW continuous / 18kW peak power — 12,000VA rated split-phase output with 18,000VA peak capacity and 6HP motor-starting capability, easily handling high-inrush loads such as HVAC compressors and submersible pumps.
3. 250A ultra-high charge current, 270A discharge — Supports rapid charging and discharging of large-capacity 48V battery banks; up to 250A PV charging, 160A AC charging, and 250A combined hybrid charging (all programmable).
4. Dual MPPT with 24kW total PV input (XP version) — Two independent MPPT trackers, each accepting up to 12,000W and 32A, with 500Vdc max open-circuit voltage and 99.9% tracking efficiency for maximum solar harvest.
5. Lithium-ready with dual activation — CAN/RS485 BMS communication with pre-configured protocols for Pylon, Dyness, Fox-ess, Gotion, Sunwoda and more; dormant lithium batteries can be activated by either mains or PV.
6. Up to 6 units in parallel — Build single-phase or split-phase systems from 12kW up to 72kW with automatic master/slave synchronization and current-sharing protection.
7. Four charging modes & three timed charge/discharge windows — Solar-only, Mains-priority, Solar-priority and Hybrid charging, plus 3 programmable time slots for scheduled charging/discharging to exploit time-of-use tariffs.
8. Works without battery — PV and utility can power loads directly even with no battery installed; also supports generator input with a dry-contact auto-start port for 24/7 off-grid operation.
9. Anti feed-in & self-consumption — With an optional external CT, the inverter limits grid export to zero and prioritizes self-consumption of solar energy.
10. Intelligent touch LCD & full connectivity — Touch-button LCD with dynamic power-flow diagram, USB / RS485 / WiFi (optional) monitoring, power-saving mode and uninterruptible 10ms typ. transfer between bypass and inverter output.
Front View
3/4 Front View
Side View
Back View
Bottom Panel: AC IN/OUT, Battery, PV Terminals and Communication Ports
|
Parameter |
Value |
|
Rated input voltage |
120Vac (L1-N, L2-N) / 240Vac (L1-L2) |
|
Input phase voltage range |
(85–140Vac) ±2% |
|
Input frequency |
50Hz / 60Hz (auto detection) |
|
Input frequency range |
47–55Hz (50Hz); 57–65Hz (60Hz) |
|
Max bypass overload current |
2-pole, 60A/60A (L1/L2) |
|
Bypass efficiency |
>95% |
|
Conversion time (bypass ↔ inverter) |
10ms (typical) |
|
Rated output power (split phase) |
12,000VA / 12,000W |
|
Rated output power (single phase) |
7,200VA / 7,200W (limited by wiring terminals) |
|
Peak power |
18,000VA |
|
Output waveform |
Pure sine wave |
|
Rated output voltage |
120Vac (L1-N, L2-N) / 240Vac (L1-L2); selectable 100/105/110/120/127Vac |
|
Output voltage error |
±5% |
|
Output frequency |
50Hz ±0.3Hz / 60Hz ±0.3Hz |
|
Power factor |
1 |
|
Max inverter efficiency |
>91% |
|
Loaded motor capability |
6HP |
|
Overload protection |
105%–110%: shut down after 5 min; 110%–125%: after 10 s; >125%: after 5 s |
|
Output short-circuit protection |
Protected after 1 second of continuous short circuit |
|
Parameter |
Value |
|
Battery type |
Lead-acid (GEL / SLD / FLD / USER) or Lithium (LFP15 / LFP16 / NCM14 / USER) |
|
Rated battery input voltage |
51.2V (minimum starting voltage 44V) |
|
Battery voltage range |
40.0–58.6Vdc (alarm / cutoff / recovery points settable on LCD) |
|
Max AC charging current |
160A (settable) |
|
Max PV charging current |
250A (settable) |
|
Max hybrid charging current (AC + PV) |
250A (settable, 0–250A) |
|
Max battery discharge current |
270A |
|
Lithium BMS communication |
CAN / RS485 (RS485-2/BMS port) |
|
Supported BMS protocols |
Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, Pylon V3.5 / CAN, EVI, Voltronic |
|
Lithium battery dual activation |
Activated by mains or PV when battery is dormant |
|
Timed charge / discharge |
3 programmable time slots each |
|
Parameter |
Value |
|
Number of MPPT trackers |
2 (independent) |
|
Max PV array power |
12,000W + 12,000W (total 24,000W) |
|
Max PV open-circuit voltage |
500Vdc |
|
PV operating voltage range |
90–485Vdc |
|
MPPT voltage range |
90–450Vdc |
|
Start-up voltage |
120Vdc |
|
Max PV input current |
32A + 32A |
|
MPPT tracking efficiency |
99.9% |
|
PV wiring / breaker recommendation |
8AWG (8.3mm²) cable, 2-pole 40A DC breaker |
|
Parameter |
Value |
|
Permitted parallel number |
1–6 units (XP model) |
|
Parallel configuration |
Single-phase or split-phase, up to 72kW total |
|
Battery wiring / breaker recommendation |
00AWG (67mm²) cable, 2-pole 300A breaker |
|
AC input/output wiring recommendation |
6AWG (13mm²) cable, 2-pole 63A breaker |
|
Certification |
UL 1741 / CSA C22.2 No. 107.1 |
|
EMC level |
FCC Part 15 Class B |
|
Operating temperature |
−10°C to 55°C (derating above 45°C) |
|
Storage temperature |
−25°C to 60°C |
|
Humidity |
5%–95% (conformal coating protection) |
|
Noise |
≤60dB |
|
Cooling |
Forced air cooling with variable-speed fan |
|
Communication interfaces |
USB / RS485 / WiFi (GPRS, optional) / dry contact / external CT |
|
Dimensions (W × H × D) |
620 × 450 × 132mm |
|
Weight |
23.8kg |
1. Whole-home backup power — As the energy hub of a residential solar + storage system, the 12kW split-phase output runs 240V central air conditioners, well pumps, electric dryers and ranges, while the 10ms typ. transfer keeps routers, computers and refrigerators running seamlessly through outages.
2. Off-grid homes and cabins — With 24kW of PV input capacity and support for generator auto-start via the dry contact port, the unit forms a complete off-grid power system with no utility connection required.
3. Self-consumption and time-of-use optimization — With the optional external CT, solar energy is prioritized for household loads with zero grid export; the 3-slot timed charge/discharge schedule lets the battery charge at off-peak rates and discharge during peak-price hours.
4. Scalable light-commercial systems — Parallel up to 6 units for 72kW single-phase or split-phase capacity, ideal for workshops, farms, small shops and telecom sites with growing power demands.
Yes. The GES48120M250-500XP supports battery-less operation: PV power and utility power can supply your loads simultaneously even with no battery installed. This makes it usable as a pure grid-tied backup solution, with the option to add batteries later. Note that when no battery is present, the inverter cannot provide backup during a grid outage at night.
12KW 48V Split Phase 120V 240V Hybrid PV Inverter supports both lead-acid (sealed/GEL/vented, with preset charge parameters) and lithium batteries. For lithium, set the battery type to LFP15 (15-cell LiFePO4), LFP16 (16-cell LiFePO4), NCM14 (14-cell ternary) or USER, then enable BMS communication via CAN or RS485. Pre-configured protocols are provided for Pylon, Aoguan, Oulite, Gotion, Sunwoda, CF, Dyness, Pace, BST, Fox-ess, AEC, EVI, Voltronic and more — simply connect the battery's RJ45 BMS cable to the inverter's RS485-2/BMS port and select the matching protocol in the LCD menu.
We recommend a battery bank of at least 300Ah at 48V. For lithium batteries, a 300Ah bank accepts 250A charging at roughly 0.8C; for lead-acid batteries, the recommended charge current is 0.2C, so a bank of 600Ah or more is preferred to use the full charging capability. Charging parameters (charge voltage, float voltage, cutoff and recovery points) are all adjustable on the LCD for custom batteries.
Yes. The unit delivers 12kW continuous split-phase power with an 18,000VA peak capacity and a rated motor-starting capability of 6HP. Overload handling is progressive: 105%–110% load runs for 5 minutes, 110%–125% for 10 seconds, and above 125% for 5 seconds before shutdown. With the overload auto-restart option enabled, the inverter retries after 3 minutes (up to 5 times in 30 minutes), which absorbs the start-up surge of compressors and pumps without user intervention.
Two independent MPPTs are available, each rated for a maximum of 12,000W and 32A input. Keep each string's open-circuit voltage at or below 500Vdc (absolute maximum), stay within the 90–450Vdc MPPT window, and note that MPPT tracking starts at 120Vdc. Both series and parallel string configurations are supported; install a 2-pole 40A DC breaker per MPPT input and use 8AWG PV wire. Never connect one PV string to more than one inverter.
Yes — the XP model supports paralleling up to 6 units in either single-phase (all L1/L2 outputs tied together) or split-phase configuration, for a total system of up to 72kW. Parallel communication runs over shielded DB15 cables with automatic master/slave address assignment, and the system provides dedicated protections for current sharing, battery voltage difference and AC input consistency. Settings made on the master unit automatically synchronize to all slaves.
The 12KW 48V Split Phase 120V 240V Hybrid PV Inverter works with an optional external CT sensor for anti feed-in (zero export) and self-consumption control: it dynamically limits grid injection to the programmed zero-export power threshold. Please note this inverter does not carry grid-interconnection certification, so grid export functionality is intended for off-grid or export-limited applications only — confirm local regulations before any grid-interactive installation.
In bypass (mains priority) mode, the unit switches from grid to inverter output in a typical 10ms, comparable to a line-interactive UPS, so most electronics continue running without interruption. Two output modes are available (mains bypass and inverter output), and PV charging continues unaffected during the switchover.
Yes. By enabling the "Line Chg without zero" parameter, the unit can charge its batteries from a 230V single-phase mains supply. In this mode the AC output must serve only 230V loads — do not connect 120V loads while operating with 230V input charging.
Three independent charging windows and three discharging windows can be programmed (each to the minute, 00:00–23:59). For example, you can allow grid charging only during off-peak night hours and force battery discharge during expensive evening peak hours, maximizing savings under time-of-use tariffs. The inverter also supports four charging strategies: solar-only, mains-priority, solar-priority and hybrid charging.
Out of the box, the unit offers a touch LCD with a dynamic power-flow screen, plus USB (PC monitoring software) and RS485 ports. An optional WiFi/GPRS dongle enables remote monitoring of system status, real-time power flow, historical data and fault alarms from a phone or PC. A dry-contact port can auto-start/stop a diesel generator based on battery voltage, and a second dry-contact allows remote ON/OFF control of the AC output.
The 12KW 48V Split Phase 120V 240V Hybrid PV Inverter provides 360° all-round protection: PV reverse-polarity and night reverse-current protection, PV over-voltage/over-current and insulation (ISO) monitoring, battery over/under-voltage and over-current protection, output short-circuit and overload protection, AC input over/under-voltage protection, leakage current detection, over-temperature protection with variable-speed fan cooling, and complete parallel-system fault monitoring (communication loss, current sharing, ID conflict and firmware mismatch detection).
Each package contains the inverter, user manual, ring terminal × 2, expansion bolts/screws, dust cap × 2, hexagonal flange nut × 2, warranty card and certificate. Warranty terms follow the warranty card included with your unit — please contact our sales team for detailed warranty policies and extended service options for your region.
Address
No. 82, Xiaotang Gongye Avenue, Shishan Town, Nanhai District, Foshan City, Guangdong Province, China
Tel