Products
2kVA Automatic Voltage Regulator
  • 2kVA Automatic Voltage Regulator2kVA Automatic Voltage Regulator

2kVA Automatic Voltage Regulator

Model:AVS-2000VA
As a professional manufacturer of power equipment, KTAC has launched the 2KVA Automatic Voltage Regulator (AVR). This tower-style AC voltage regulator is designed for medium-scale power applications with a rated capacity of 2000VA / 1200W, making it suitable for small shops, studios, medical equipment, and the centralized protection of multiple household appliances. Powered by MCU control and zero-crossing switching technology, it delivers a stable output of 180–255VAC (with ±8% accuracy) from a wide input range of 130–270VAC.

Rated Capacity: 2000VA / 1200W

Input Voltage Range: 130–270VAC

Output Voltage Accuracy: ±8%

Protection Types: Over-voltage, under-voltage, over-temperature, overload, short-circuit

Suitable Loads: Refrigerators, air conditioners, computers, printers, small motors, etc.

In real-world applications, voltage instability is a primary cause of electrical equipment failure. The AVS-2000 is designed for centralized voltage regulation of medium-power loads; a single unit can support the combined needs of a small supermarket (checkout systems, freezers, and lighting) or a studio (multiple computers, printers, and air conditioners).

Its MCU core monitors the input voltage dozens of times per second. When voltage fluctuations occur, 2KVA Automatic Voltage Regulator automatically switches toroidal transformer taps to maintain a stable output between 180V and 255V. A specially designed 6/180-second startup delay prevents surge damage to compressor-based loads immediately after voltage recovery.

For equipment requiring 24-hour continuous operation (such as servers or surveillance systems), the AVS-2000 ensures long-term stability thanks to its low-loss toroidal transformer and intelligent temperature-controlled fan (optional).

Key Features

1. Wide Input Voltage Range

2KVA Automatic Voltage Regulator accepts an input voltage of 130–270VAC, making it suitable for areas with severe grid fluctuations, such as rural locations, older residential complexes, or industrial zones. It automatically cuts off the output when the voltage drops below 130V or exceeds 270V to protect downstream equipment, and automatically restarts once the voltage stabilizes, requiring no manual intervention.

2. 7-Tap Precision Voltage Regulation

Utilizes a toroidal autotransformer with seven independent taps and relays to achieve regulation steps of approximately 15–20V per stage, resulting in an output accuracy of ±8%. Compared to servo-motor-type stabilizers, it offers faster response times (<40ms) and eliminates mechanical wear.

3. Toroidal Transformer Advantages

· Efficiency >96% with low internal heat generation

· Low magnetic leakage; does not interfere with nearby electronic equipment

· Quiet operation (<40dB); suitable for office or retail environments

4. Multiple Protections + Delayed Start

· Over-temperature shutdown: Automatically cuts output if internal temperature reaches ≥120°C

· Short-circuit protection: 12A resettable circuit breaker/fuse

· Overload protection: Cuts power if load exceeds 1200W for several seconds

· Over-voltage/Under-voltage protection: Cuts power if output voltage falls outside the 180–255V range

· Delay selection: 6 seconds (standard equipment) or 180 seconds (air conditioners/refrigerator compressors)

5. Dual LED Voltmeters

The front panel features separate voltmeters for input and output voltages, allowing real-time monitoring of mains power quality and stabilization performance. Three-color LEDs—Power (Green), Delay (Yellow), and Fault (Red)—provide clear status indication at a glance.

6. Compact Tower Design

Dimensions: 330×225×265mm; Net weight: 4.9kg; suitable for desktop or floor placement. Features front-and-rear ventilation and supports stacking (units from the same series can be stacked; total power load must be considered).

Product Parameter

Model AVS-2000VA

Parameter

Value

Nominal Power

2000VA

Rated Power

1200W

Power Factor

0.6

Input

Regulation Voltage

130~270VAC

Range

Power cord with plug

Output

Output  Voltage Range

180~255VAC

High Cut Voltage

255V

Low Cut Voltage

180V

Frequency

50/60Hz Auto Sense

Safety Cycle

6 Seconds / 180 Seconds Selectable

Connection Type

Output sockets

Regulation

Regulation %

± 8% (when input 130~270VAC)

Number of Taps

7 taps

Transformer Type

Toroidal auto transformer

Regulation Type

Relay type

Indicators

LED indicators

POWER: Green LED ON, Delaying: Yellow LED ON, Fault / Protection: Red LED ON

Voltage Meter

1 input & 1 output LED volt meter

Protection

Over Temperature

Auto Shutdown at 120 ℃

Short Circuit

Auto Shutdown

Breaker / Fuse

12A

Overload

Auto Shutdown

Over / Under Voltage

Auto Shutdown

Physical

Dimension

210*155*190mm

Net weight

4.9kgs

Product Applications

1. Small Shops / Convenience Stores

Simultaneous protection for: POS computer (300W) + 2 freezers (600W) + lighting (200W). The AVS-2000 delivers 1200W of continuous power and handles peak startup surges of up to 2000VA, making it a highly cost-effective choice.

2. Residential Central Air Conditioning / Multiple Air Conditioners

A single 1.5 HP air conditioner has an operating power of approximately 1000W, with a startup surge reaching up to 3000W. The 2KVA Automatic Voltage Regulator can power one 1.5 HP air conditioner, a refrigerator, and a router simultaneously. It is recommended to set the air conditioner startup delay to 180 seconds.

3. Photography Studios / Print Shops

Equipment such as computers, high-end monitors, inkjet/laser printers, and scanners is sensitive to voltage fluctuations. The AVS-2000 provides a pure sine wave output (without waveform distortion), preventing issues like printer paper jams or image distortion.

4. Medical Equipment (Clinics)

Devices such as small X-ray machines, dental chairs, and oxygen concentrators require stable voltage. The AVS-2000 complies with IEC standards; using it in conjunction with a medical-grade isolation transformer is recommended.

5. Generator Integration

When generator output is unstable, connecting the AVS-2000 smooths the voltage waveform, protecting downstream precision equipment. Suitable for applications such as food trucks and outdoor events.

Selection Guide & Comparison

Total Load Power

Recommended Model

Description

<600W

AVS-1000

Single computer + router + monitor

600-1200W

AVS-2000

Small shops, multiple household appliances

1200-1800W

AVS-3000

Air conditioner + refrigerator + microwave oven

1800-3000W

AVS-5000

Whole household or small workshop

Note: Inductive loads (motors, compressors) have startup currents 3–7 times their rated value; a 50% power margin is recommended.

Customization Services

KTAC offers OEM/ODM services for the AVS series, including options for housing color, logo silk-screening, output socket types (Chinese, US, EU standards, etc.), input cable length, and preset delay times. Please contact us for a customized solution.

FAQ

1. Can the AVS 2KVA Automatic Voltage Regulator power a 2 HP air conditioner?

A 2 HP air conditioner has an operating power of approximately 1500W and a startup surge of about 4000W. The AVS-2000's maximum output current limit (12A circuit breaker) may cause the unit to trip during startup. We recommend choosing the AVS-3000 (16A) or a higher-capacity model.

2. Why isn't the output voltage a constant 220V?

The AVS series utilizes a relay-based tap-switching voltage regulation design; the output range is 180–255V with an accuracy of ±8%. For precision equipment requiring 220V ±3%, a servo-type voltage stabilizer or an online UPS is recommended.

3. Can two AVS-2000 units be connected in series?

This is not recommended. Connecting two units in series can lead to mismatched response speeds and potential oscillation. If cleaner voltage is required, a filter can be installed downstream of the AVS-2000.

4. How do I determine if a voltage stabilizer is needed?

Measure the outlet voltage with a multimeter; installation is strongly recommended if the voltage exceeds 240V during the day or drops below 190V at night, or if you observe flickering lights or frequent computer restarts.

5. What precautions should be taken during installation?

· Avoid placing the unit near heat sources (e.g., heaters, generator exhaust pipes).

· Leave a 10cm clearance on the sides and back for heat dissipation.

· Do not stack heavy objects on top of the unit.

· It is recommended to install a Type C circuit breaker (16A rated) at the input.

6. What should be done if the unit is not used for an extended period?

Turn off the power switch and unplug the input cord. Power on the unit once every three months to maintain the health of the internal capacitors.


Hot Tags: 2KVA Automatic Voltage Regulator, China, Manufacturer, Supplier, Factory
Send Inquiry
Contact Info
We welcome your inquiries, our professional engineering team will tailor power supply solutions to your specific needs.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept